4 CLEARANCES Always allow at least a 2-inch clearance between DuraTech Chimney Pipe and any combustible materials. DuraVent - Through-The-Wall Chimney Pipe Kit This Through-the-Wall Chimney Stove as the purpose of this trip was to install the chimney…, INSTALLATION AND OPERATION INSTRUCTIONS A MAJOR CAUSE OF CHIMNEY RELATED FIRES IS FAILURE be sure to contact either your dealer or Simpson Dura-Vent …. Hardware included. Always maintain a minimum of 2” clearance between chimney pipe and nearby combustibles. DuraSeal® FasNSeal® PolyPro® Common Vented Appliances. Mid Efficiency, Natural Gas / Propane, Stand-Alone Installation. DVL's double-wall, air-insulated design reduces clearances to combustibles from 18 in. Step 3: Before proceeding, take Close. Check your owners manual for approved chimney companies, and other restrictions such as distance for a horizontal run. NOTE: The connector (CC-C) is the only component that can connect pipe to chimney; therefore a close Page 1 Installation Instructions All-Fuel Chimney System...; Page 2 Read through all of these instructions before We welcome any comments regarding matters beginning your installation. DVL 6 in. Free Shipping on orders $129 or more. 3. Features Fullscreen sharing Embed Statistics Article stories Visual Stories SEO. Place the storm collar over the pipe and insert the tab into the first slot, then back up through the second slot, and then bend the tab back over the slots to secure it into place. Refer to the DuraTech Chimney Installation Instructions for complete details ... president@duravent.com If you are searching for tech support or product information, please phone us at 800-835-4429. Type B Gas Vent; DuraFlex® Aluminum; DuraLiner® DuraFlex® Stainless Steel; High Efficiency, Natural Gas / Propane. ... chimney pipe with at least a 1/2” upturned flange/collar. Never fill any required clearance space with insulation or any other materials. Following is a typical installation for a duravent direct vent chimney system installation. FasNSeal® Installation Instructions (PDF, 1.9MB ) FasNSeal® Installation Instructions FR (PDF, 1.9MB ) FasNSeal® Supplemental instruction – Fixed Damper (PDF, 470KB ) FasNSeal® Rain Cap Guy Wire Attachment Installation Instructions Addendum (PDF, 107KB ) Combustible materials include Subtract 1 1/4" per joint of DuraBlack stovepipe. Subtract 1 1/2" per joint of DVL stovepipe. Bend and trim the base of the of the hole where the lateral pipe Section Tall cone Flashing so it fits onto the top of the is to pierce the masonry chimney. Installation Instructions - M&G DuraVent. Download stove and chimney pipe installation guides and Manuals for all brands: Simpson Dura Vent, Metal-Fab, Metalbestos, SuperPro and more! Important: Check the manufacturer’s rating plate and instruction manual to confirm that the DuraVent direct vent system is ap-proved for use on the brand name appliance you have selected. For PolyPro (female) to Metal Vent (Male) connections, the metal fittings will have a Locking Button or Protrusion, and will be connected simliar to Fig. Issuu company logo. • Measure the diameter of the appliance ˛ue outlet. installation instructions & maintenance guide (canada & united states) ... ceiling support installation stove pipe adaptor attic insulation shield installation ... specifically approved for that type of installation. When starting your bead apply it just a bit higher than the top of the flashing this allows a good seal to be made when pulling the Storm Collar down over the flashing. Installation instructions can be viewed online at www.duravent. DVL double-wall stovepipe completes the venting system when used with one of DuraVent’s chimney products, such as DuraTech, DuraPlus, or DuraPlus HTC. Stove Pipe Adapter (ASE) Decorator Ceiling Support Chimney Length STOVE PIPE ADAPTER (ASE) STOVE PIPE ADAPTER The Stove Pipe Adapter (ASE) is installed by twist-locking it into the bottom end (female end) of the first Chimney Section that enters the See separate installation instructions for more details. • The diameter of the chimney should match the outlet size of the appliance. Step 2: Ensure the appliance has a DirectVent specific Appliance Adapter installed to mate with the proprietary DirectVent Twist-Lock feature. POLYPRO TO DURAVENT / SECURITY CHIMNEY METAL VENT CONNECTION Approved M&G Duravent / Security Chimney 1738/636 metal vent fittings can be used with PolyPro. Always follow DuraVent Installation instructions before installing your chimney system. Installation instructions can be viewed online at www.duravent.com, under Catalogs and Instructions. Set the appliance roof (more than 7/12 pitch) ,use the height as stated in Table 2. in it’s desired position, and mark the center (g). Snap the connector (CC-C) into the support box, or into the wall thimble. Subtract 1 … Note: the outer wall is 2" larger diameter than the innner wall and sizes listed are inside diameters (Ex: 10" inner pipe has a 12" outer pipe). The diameter of the chimney should match the outlet size of the appliance. The Simpson Dura-Vent warranty … To calculate the installed per length of 5"-8" DuraTech pipe, subtract 1 1/4" per joint. Using the Typical Venting Installation drawings, select the appropriate component parts for your installation. For the most up-to-date installation instructions, see www.duravent.com All-fuel ChImney SyStem NorthlineExpress.com www.NorthlineExpress.com Toll-Free 1-866-667-8454 DVL/DuraBlack Chimney Adapter or DuraBlack Slip Connector must be used when connecting DVL or DuraBlack stovepipe to a Ceiling Support, Wall Thimble, or Finishing Collar. Installation Instructions - M&G DuraVent. WARNING DuraTech Chimney system is listed with a 2” minimum clearance (air space) to com-bustibles. Locate Appliance. Copyright © 2020 - Leaders in-Venting InnovationTM, DuraTech® Premium Installation Instructions FR, PolyPro® for Multiple Vents (dual language), DirectVent Pro Installation Instructions English Version, Pro Française Instructions d’installation, Pro Instructions: Converting A Class-A Metal Chimney or A Masonry Chimney to A DirectVent, Pro Horizontal Colinear Reline Kit Installation Instructions, DuraChimney® II Manuel d’instructions d’installation, DuraChimney® II Instrucciones de instalación, DuraTech® & DuraChimney® II European Copper Pots Instructions, DuraChimney® II New Chimney Cap Assembly Installation Instruction Addendum, Flexible Chimney Liners Installation Instructions, Factory Built Chimney Relining Installation Instructions, DuraLiner® Masonry Thimble L402 Installation Instruction Addendum, DuraSeal® Adjustable Length Install Instructions, Adjustable Length Installation Instruction Supplement, Universal Support Installation Instruction Supplement, DuraTech®: New Chimney Cap Assembly L1510 Installation Instruction Addendum, DuraTech® 10″-24″ Installation Instructions, DuraTech® & DuraChimney II European Copper Pots Instructions, DuraTech® Canada Installation Instructions, DuraTech® Canada Installation Instructions FR, DuraTech® Premium Installation Instructions, FasNSeal® Supplemental instruction – Fixed Damper, FasNSeal® Rain Cap Guy Wire Attachment Installation Instructions Addendum, FasNSeal® 80/90 Installation Instructions, PelletVent® for multi-fuel Installation Instructions, PelletVent® for multi-fuel Installation Instructions FR, PelletVent® for multi-fuel Espanol Instrucciones de instalación, PelletVent® Pro Installation Instructions, PelletVent® Pro Installation Instructions FR, Factory-Built Chimney Relining Supplemental Installation Instructions for PelletVent®, PolyPro® Single Wall & Concentric Installation Instructions, PolyPro® Double Wall Installation Instructions, PolyPro® Double Wall Installation Instructions FR. Joe shows you how to install DuraTech DVL Double Wall Stove Pipe. Note the suggestion regarding wall thimble installation under Step #4 — Through the Wall installations. Chimney Adapter in Black DVL double-wall stovepipe completes the venting DVL double-wall stovepipe completes the venting system when used with one of DuraVent's chimney products, such as DuraTech, DuraPlus, or DuraPlus HTC. DuraTech chimney pipe connects with screws at each connection point. Chimney or Masonry Relining Installation. combustibles. Chimney Sweeps, nFI Certified Specialists, or WeTT Certified Professionals. Click Here http://www.northlineexpress.com/ to see all of our Chimney Pipe. For 10"-24" diameter, subtract 3/4" per joint of pipe. installation instructions in your DuraPlus or DuraTech Kit. Determine the total length of chimney and stovepipe required for the installation. An improperly sized chimney results in poor draft and excessive creosote formation. INSTALLATION PRECAUTIONS The Simpson Dura-Vent Direct Vent System is an engineered product that has been designed and tested for use with an approved list of direct vent gas appliances. DVL’s double-wall, air-insulated design reduces clearances to combustibles from 18 in. LOCKING BAND Figure 4 POLYPRO PIPE For the most up-to-date installation instructions, see www.duravent.com. Double-wall, close clearance connectors (8 pages), Single-wall gas vent system for category ii & iv gas-burning appliances (16 pages), Manual will be automatically added to "My Manuals", Step-By-Step Directions / Ceiling Supported, Connection from Appliance to Chimney System, Fan DuraVent duraplus htc Installation Instructions Manual, Fan DuraVent DuraPlus HTC Installation Instructions Manual, Fan DuraVent DVL Installation Instructions Manual, Fan DuraVent PelletVent UL 641 Installation Instructions Manual, Fan DuraVent polypro Installation Instructions Manual, Page 4: Clearance / Permits / Applications / Notes, Page 5: Chimney Diameter / Chimney Height / Chimney Placement, Page 6: Chimney Enclosure Requirements / Stove Recommendations, Page 7: Step-By-Step Directions / Ceiling Supported, Page 14: Extended Roof Bracket Installation, Page 21: Zero Clearance Fireplace Installations. For the most up-to-date installation instructions, see www.duravent.com. Installation instructions can be viewed online at www.duravent.com. Always follow DuraVent Installation instructions before installing your chimney system (found with the cap or support box). Installation” section of the main DuraVent DirectVent Installation Instructions (L954) before beginning your install. Failure to install pertaining to our DuraVent products. The following design recommendations are general guideline to assist in the selection and design of venting components for your installation. Refer to the full DuraTech Chimney Installation Instructions for further safety details. All warranty For the most up-to-date installation instructions, see www. Try. Determine the total length of chimney and stovepipe required for the installation. DuraPlus Discount Chimney Supply Inc. 6" DVL Stove Pipe Dura Vent Chimney. To calculate the installed per length of 6"-8" DuraPlus chimney pipe, subtract 1 1/2" per joint. Combustible materials include Flashing. DuraVent reserves the right to inspect defective product to determine if it qualifies for replacement under the terms of this limited lifetime warranty. manufacturer's installation instructions. Size the vent to meet the appliance manufacturer’s specifications. Step 1: Set the gas appliance in its desired location. in the appliance installation instructions to verify that M&G DuraVent’s PolyPro Vent is allowed for use with your appliance. The directions are enclosed with the support box or cap. The following design recommendations are a general guideline to assist in the design and selection of venting components for your installation. your chimney has been tested, and listed using all of the supports, shields, etc., described 3. Failure to … An improperly sized chimney results in poor draft and excessive creosote formation. How to install DuraVent direct vent gas pipe. • Measure the diameter of the appliance flue outlet. 4 CLEARANCES Always allow at least a 2-inch clearance between DuraTech Chimney Pipe and any combustible materials. clearanceS PolyPro single-wall vent system is listed at 0" clearance to combustibles for exhaust temperatures up to 194°F (90 °C) In addition, PolyPro single-wall vent system is listed com, under catalogs and instructions. chimney system. Subtract 1 1/4" per joint of DuraBlack stovepipe. Stand-Alone Chimney Installation. to 6 in., the closest clearance to a wall of any connector pipe. • The diameter of the chimney should match the outlet size of the appliance. Never fill any required clearance space with insulation or any other materials. duravent.com to 6 in., the closest clearance to a wall of any connector pipe.