9.10.22.2. endobj Clearance from countertop to underside of nearest cabinets on both sides of cooktop, including any light rails. While you are sure to have excellent cooking experiences with where the framing, finishes, or cabinets above the range are noncombustible or are << 72 0 R 73 0 R 74 0 R 75 0 R 76 0 R 77 0 R 78 0 R 79 0 R 80 0 R 81 0 R << The vertical clearance distance is different for ⦠When planning your installation, provide for a ½-in. /XObject << INDUCTION COOKTOPS Planning Information A minimum height clearance of 159 mm is required from the top of the countertop to any combustible surface directly below the cooktop. 13 0 obj uuid:e516822d-3762-432d-a1fa-cb2a3cbfe408 >> /Next 8 0 R Additionally, anything store in the The company GE has a whole list of cooktops approved for installation above wall ovens! 2 0 obj /TT0 33 0 R 11 0 obj Here is the International Residential Code. /Marked true Fixed barriers, such as guardrails, are required where the vertical clearance is less than 80â such as at open stairways and along sloped or curved walls. cannot be maintained, a minimum clearance of 24" is required and the underside of the cabinets above the cooktop must be protected with not less than 1/4" insulating millboard covered with sheet metal not less than 0.0122" thick. stream
/DropCap /Figure INDOOR Voltage in KV Phase to earth in mm Phase to phase in mm 0.415 15.8 19.05 0.600 19.05 19.05 3.3 50.8 50.8 6.6 63.5 88.9 11 76.2 127.0 15 101.6 165.1 22 139.7 241.3 33 222.25 355.6 Minimum Electrical Clearance As Per BS:162. /Length 3614 >> 92 0 R 93 0 R 94 0 R 95 0 R] The cooktop should be half an inch above the bench and at least 2 inches from the edge. G2447.5 (623.7) Vertical clearance above cooking top. << Scenario 2 â Overhead clearance rates not specified on installation instructions. Contemporary induction cooktops can be I understand that there must be 30" clearance between range/stove top and combustible cabinets above. /CreationDate (D:20190924153042-06'00') Household cooking appliances shall have a vertical clearance above the cooking top of not less than 30 inches (762 mm) to combustible material or metal cabinets. /S /GoTo %PDF-1.6 /D [9 0 R /XYZ 322 256 0.0] For example, for a 60â Wolf range the minimum vertical clearance between the gas range and combustible materials above the range is 44â. 30" ountertop tC grate surface 31/ 8" Chassis height 21" 281/ 62 0 R 63 0 R 64 0 R 65 0 R 66 0 R 67 0 R 68 0 R 69 0 R 70 0 R 71 0 R 9 0 obj You'll also need an electrician to install a breaker-protected, 15-amp electrical circuit terminating in a grounded ele⦠/Endnote /Note >> However if the minimum height clearance is not adhered to, this will invalidate the warranty if something happened. /ProcSet [/PDF /Text /ImageC] /CropBox [0.0 0.0 612.0 792.0] endobj 17. Household cooking appliances shall have a vertical clearance above the cooking top of not less than 30 inches (760 mm) to combustible material and metal cabinets. Vertical combustible surface All horizontal clearances must be maintained for a minimum of 18" above the cooking surface. Check the Installation Instructions for the minimum vertical clearance for specific models. /K [42 0 R 43 0 R 44 0 R 45 0 R 46 0 R 47 0 R 48 0 R 49 0 R 50 0 R 51 0 R Question ... not enough vertical clearance under the wall cabinet. ����H|vN�v��/�Bl�%�3�M���������08���J�Wu��DW�K�i$%[���*����#��0$U�Oe���Z"��W�4���z�P���� ;���҃�|��-�i�:L�&�c��Ec�q��mb��hlaYq�L����Cm���:Z8�Z��[O/��zևӎ��K�va�+�ʆ�&���o�ǰ~C�MǩlM�[J��;�N��%Ep�4p�� ��>6�ѯ��A:a��x�sܦ9��z��).as}V1�*���5�?4���i}�/�? Freestanding or built-in ranges shall have a vertical clearance above the cooking top of not less than 30 inches (762 mm) to unprotected combustible material. 2â min. 4: There is no sign of any damage to the cupboard above the cooker. Electrical outlet 12" minimum below countertop 39/ 16 " 7/ 16" DRAWER Allow 7/ 16" minimum vertical clearance from the cooktop bottom (or 39/ 16") minimum depth from the countertop) to any combustible surfaces, including the upper edge of a drawer installed below the cooktop. 56 0 R 57 0 R 59 0 R 60 0 R 61 0 R 62 0 R 63 0 R 64 0 R 65 0 R 66 0 R must be provided between the level of the cooktop burners or elements and any framing, finishes, or cabinets that are placed above the cooktop burners or elements. This clearance can be reduced to 600 mm (approx 24â) when the finish is protected as per Article 9.10.22.2. NOTE: Allow 7/16” minimum vertical clearance from the cooktop bottom (or 3-11/16” minimum depth from the countertop) to any combustible surfaces, such as a cabinet drawer. :2{��*N�J�����'��6h� ���9�C���^r��/��IJ�De��הF��ɸ^�~$��:��&DG �C]� �i����OI۳�i�����k�hQ��5v`�
�*��� /Chart /Figure endobj >> >> >> /T1_2 29 0 R /CropBox [0.0 0.0 612.0 792.0] 101 0 R null 102 0 R null null 103 0 R null 104 0 R null null >> Framing, finishes, and cabinetry installed directly above the location of the range shall not be less than 30" above the level of the electric or gas range burners or elements. /Length 1166 NOTE: The clearance requirements might be different depending on the manufacturer, model and construction codes of the state. The Teppanyaki Module in accordance with the cooking appliance manufactureâs instruction. 17 0 obj /Im0 34 0 R /Filter /FlateDecode /TextBox /Art /Artifact /P uuid:2f1c6dbb-6376-4f46-9de4-82db6327a231 November 19, 2005. The vertical clearance distance is different for different manufacturers. /T1_3 30 0 R /Filter /FlateDecode (ii) a metal hood with a 125 mm projection beyond the framing, finishes and cabinets. Gas cooktops are set up at the factory to operate using natural gas, but most manufacturers also offer propane conversion kits for installations where natural gas isn't available. H��WM��8��W�h-�K�l(z�i]��=�6(n>��M�A�I��~I��c;�l{�I$����$B������2+��/���x+21_Ξ�2-�ɪ�i.���2�}��~ܫ�/�֤7WDs�+
���qS�������F�. /Creator (Acrobat PDFMaker 18 for Word) 30" MIN. The clearance required between the level of cooktop burners or elements and framing, << << << /T1_1 28 0 R 4: There is no sign of any damage to the cupboard above the cooker. 14 0 obj So, to prevent this from happening, your stove should be installed following the instructions from the Australian Standard AG/601- AS560. /Last 8 0 R /Company (ITO) 610 mm, 762 mm and 914 mm Cooktops STANDARD INSTALLATION 610 mm, 762 mm and 914 mm Cooktops FLUSH INSTALLATION E A RECESS 537 mm RECESS 40 mm min W CUT-OUT WIDTH COUNTERTOP CUT-OUT 495 mm 64 mm 64 mm 254 mm 114 mm 89 mm SIDE VIEW FRONT VIEW NOTE: Shaded area above countertop indicates minimum clearance to ⦠clearance height. We stock 60cm and 90cm cooktops from all the big brands such as … Maintain 3 in. Ontario Code for clearance above a gas range cook top for either the range hood or cabinets is listed below, also check the spec’s for the gas range and the range hood Clause 7.32.4 – Except where permitted by Clauses 4.13.2 and 7.32.5 to 7.32.7, a residential type range shall have the following minimum clearances to combustible material: An Electric, Induction, or Gas Cooktop can be installed above a wall oven: 1/4" clearance is required between all cooktops and wall ovens. >> Make sure the wall coverings, countertop and cabinets around the cook-top can withstand heat (up to 200 degrees F) generated by the cooktop. Combustibles /T1_5 32 0 R /T1_4 31 0 R There should be a clearance of 4 inches between the in-bench safety barrier and the bench bottom. /ExtGState << Allow 7/ 16" minimum vertical clearance from the cooktop bottom (or 3â¹/16") minimum depth from the countertop) to any combustible surfaces, including Clearance from cutout to nearest vertical wall or cabinet on right side of the unit below the 15” MIN. /Lang /Superscript /Span endobj /ProcSet [/PDF /Text /ImageC] /Im0 41 0 R << q��.�~&����N�U���wX��d��P�n�v�WBA���DI�#T����������~���t`_:�{TS,��'��|FJ��貃Z�v|�
��2B�fC�er`��w�F�C�g�v�D[����_�}�c��潛� ;�Q�� /ModDate (D:20191119153759-06'00') rigid gas line with a shutoff valve within 3 ft. of the cooktop location. /Subtype /XML /Strikeout /Span /CS1 [/ICCBased 25 0 R] >> endobj combustible vertical surfaces above 36â (91.4 cm), the maximum wall cabinet depth must be 13â (33.0 cm) and wall cabinets within this 6â (15.2 cm) side clearance must be 18â (45.7 cm) above the 36â (91.4 cm) high countertop. Electrical outlet 12" minimum below countertop Hol 39/ 16 " 7/ 16" DRAWER Allow 7/ 16" minimum vertical clearance from the cooktop bottom (or 39/ 16") minimum depth from the countertop) to any combustible surfaces, including the upper edge of a drawer installed below the cooktop. Hi, I recently bought a GE Induction Cooktop (Model #PHP960), and I'm a little confused about the vertical clearance requirements. Where clearances are not specified by the manufacturer, then clearance distances shall be as described in AS/NZS 5601: 2013. /A 15 0 R Betta has the most extensive range of quality cooktops to buy online or in-store. >> 82 0 R 83 0 R 84 0 R 85 0 R 86 0 R 87 0 R 88 0 R 89 0 R 90 0 R 91 0 R << /Outlines 3 0 R Horizontal or vertical clearances on the sides of the range to unprotected combustibles must be a minimum of 450 mm (18â) above the level of the heating element. Vertical Clearances above Cooktops. /T1_0 28 0 R Vertical combustible surface E Rear Wall Minimum distance to combustible side wall above countertop (both sides) 27/ 8" 12" 12" 95/ 81 " 281/ 2" Min. 105 0 R null 106 0 R null null 107 0 R null 108 0 R null] >> Vertical Clearance [§307.4] 18. NOXTON Ceramic Cooktop Built-in 2 Burners Electric Cooktops Stove Electric Hob Cooker With Touch Control Child Lock Timer Easy To Clean 3000W with Hard Wire for 220V~240V 4.3 out of 5 stars 43 Tools & Home Improvement endobj endobj GE recommends 12 inches GE recommends 12 inches There are fixing brackets or sealants to be used to fix or fasten the induction hob depending on different manufacturers. Something like 16 inches to range hood or bottom of microwave or oven. Clearance from countertop to /T1_4 40 0 R /Subscript /Span >> /Rotate 0 )+�-ÿ'� We can see from the Title Information Block (Fig 2.10) that vertical heights above sea level are also measured in metres. Min. For island installation, maintain 2-1/2 in. /Author (Hawkins, William GR) /SourceModified (D:20190924212755) /Underline /Span /Footnote /Note (30â) and 2â min. Min. minimum from cutout to front and back edge of countertop. >> /Annotation /Span /ColorSpace << The clearance can be reduced to 600 mm (24ââ) above the level of the elements or burners provided the framing, finishes and cabinets noncombustible or has a metal hood with a 125 mm (5â) projection beyond the framing, finishes and cabinets. /Filter /FlateDecode �"�H�_7���h�Q��}�`�[b�)0�����O�Ɇ�b��'¨>9x�N_�;Y���y����A�}l��f4�|�ߠ-�B|���? D:20190924212755 above the bench top. >> ] Barriers must have leading present vertical clearance above mean sea level may be determined for the 500-foot midwidth of Paris Road Bridge by using a present, reported and nearby water height, in feet, relative to mean sea level clearance of 140 feet. Acrobat PDFMaker 18 for Word 6 0 obj That won't invalidate a warranty and I've seen /First 7 0 R Reduced clearances are permitted in accordance with the listing and labeling of the range hoods or appliances. /Title (Building Advisory: Clearance Above Cooktops) /XObject << 18 0 obj ����%�&����R�X��)Շ{62D�9!�Z|rL�����L"w���0[�����! Gas cooktops HCG604W models. Additionally, anything store in the drawer must NOT be combustible. Vertical Clearances above Ranges of the Alberta Building Code. In gen-eral, it consists of an imaginary box, 30-inches square, extending at least 40 inches above the highest communications cable or other Freestanding or built-in ranges shall have a vertical clearance above the cooking top of not less than 30 inches (762 mm) to unprotected combustible material. endstream >> >> M1901.2 Cooking appliances. << /Type /Metadata %���� (1) Except as provided in Sentence (2), framing, finishes and cabinetry installed directly above the location of the cooktop shall be not less than 750 mm above the level of cooktop burners or elements. >> /CS1 [/ICCBased 24 0 R] between a gas cooking appliance and a combustible surface shall be . The True Induction TI-2BN Vertical Double Burner Counter Inset Cooktop is one of the best cooktops on the market. A vertical clearance of at least 750 mm (30 in.) /Type /Catalog 2019-11-19T15:37:59-06:00 >> (2) The vertical clearance described in Sentence (1) for framing, finishes and cabinets located directly above the location of the cooktopis permitted to be reduced to 600 mm above the level of the elements or burners provided the framing, finishes and cabinets, (i) asbestos millboard not less than 6 mm thick, covered with sheet metal not less than 0.33 mm thick, or. /Parent 3 0 R endobj /C0_0 38 0 R /RoleMap 13 0 R application/pdf 67 0 R 68 0 R 69 0 R 70 0 R 96 0 R null 71 0 R 72 0 R 73 0 R 74 0 R endobj /Outline /Span }��K���'�τh�������݇Xz���FZ��]ڂ܅�5P��Z���sI��8`糾z��Qi���7�Vd@b|�����-nV��[������//���ŋ�p�7 HV�A�4���?ذ����w�u{xm�@��:����-��Gw�7 lc
{b����K2P��n����Zw�����������#�~���/4�>�(x[р��� 25 COOKTOPS - LOCATION & CLEARANCE SPACE Vertical clearances above cooktops The minimum clearance required directly above the location of the cooktop is 750 mm (30 inches) from the level of the cooktop burners or elements to framing, finishes and cabinetry. /PageLayout /OneColumn Vertical combustible surface All horizontal clearances must be maintained for a minimum of 18" above the cooking surface. † Within the 6” (15.2 cm) side clearance to combustible vertical surfaces above 36” (91.4 cm), the maximum wall cabinet depth must be 13” (33.0 cm) and wall cabinets within this 6” (15.2 Min. Make sure the wall coverings, countertop and cabinets around the cook-top can withstand heat (up to 200 degrees F) generated by the cooktop. Reduced clearances are permitted in accordance with the listing and labeling of the range hoods or appliances. /K 11 0 R 94 0 R 95 0 R 87 0 R] /Type /Page /CS0 [/ICCBased 24 0 R] << /Diagram /Figure >> (36â) Clearance from cutout to nearest vertical
/Type /StructTreeRoot All other ventilation units require 25" 1/2 - 31" 1/2 clearance from cooking surface. << /GS0 26 0 R endobj Clearance is measured from the bottom of the cooktop burner box. << Clearance from cutout to nearest vertical wall or cabinet on left side of the unit below the 15â MIN. endobj >> Vertical Heights, on the other hand, are measurements of features above the high tide level including lighthouses, mountains, bridg⦠The /S /GoTo << /T1_1 29 0 R endobj /Tabs /S At above left we have lifted the old gas cooktop, a Jennair unit, partly out of its countertop to measure its depth. See below. >> /Count 2 This material is COPYRIGHT © QUEEN'S PRINTER FOR ONTARIO, 2008-2018. A minimum clearance of 24 inches (610 mm) is permitted where one of the following is installed: The underside of the combustible material or metal cabinet above the cooking top is protected with not less than 1 / ⦠Contents 1 Safety and warnings 2 Installation instructions 6 ... A minimum clearance of 20 mm has to be kept between the base of the cooktop and the top ... vertical combustible surfaces above). /Title (NBC 2015, Division B, Article 9.10.22.2.) 16 0 obj 15 0 obj /D [9 0 R /XYZ 322 271 0.0] >> /Length 1194 endobj For a Thermador range the distance to the bottom of the hood is 30â, and 40â to an unprotected cabinet. Reduced clearances are permitted in accordance with the listing and labeling of the range hoods or appliances. Electric Cooktops This clearance varies by model. I wanted to put a drawer under the cooktop, but the manual says things that seems somewhat contradictory, and I'm having a little trouble deciphering between CYA speak and real concerns. /Title (Vertical Clearance Above Cooktops) 15â min. This site is not an offical copy or maintitned by the Government of Ontario. Because certain appliances, like gas cooktops, use open flame to operate, which is a potential hazard for your house and the surrounding environment. /Parent 4 0 R Vertical and clearance heights Measurement of Vertical and Clearance Heights We can see from the Title Information Block (Fig 2.10) that vertical heights above sea level are also measured in metres. /Contents [16 0 R 17 0 R 18 0 R 19 0 R 20 0 R 21 0 R 22 0 R 23 0 R] Many translated example sentences containing "vertical clearance above" â French-English dictionary and search engine for French translations. for a minimum of 18" above the cooking surface. Headroom clearance of at least 80â high is required along all circulation paths. 52 0 R 53 0 R 54 0 R 55 0 R 56 0 R 57 0 R 58 0 R 59 0 R 60 0 R 61 0 R �Z&��~�8r-+��J4���F(V�p������?��;aY1�?W�.$�ID�B��#,Z��5��H��9�U#+��+4W >> Vertical Clearances above Cooktops. Scenario 2 – Overhead clearance rates not specified on installation instructions Where the manufacturers of the gas cooking appliance and the rangehood / exhaust fan do not specify a minimum clearance rate, then the practitioner must provide a clearance rate of no less than 600mm for a rangehood and no less than 750mm for an exhaust fan, in accordance with … /Font << 12 0 obj /Prev 7 0 R However if the minimum height clearance is not adhered to, this will invalidate the warranty if something happened. endobj 4 0 obj H��V�n�F}�W�#��V�+I HaIn�1b�@점%�V#Q�D���wf/$%�iP��po�s=g��ٮ]}�/Zx�z|ֶ��}����d۶�
|O&�?�Z)�2mAIn��(�-J������_5��n�z�ʭ���Vͼ]mx�f2�B�%Q�{Z�(%/���θ��Р����I8�JY���b*ß(��Q�K�09,6���&��6��?R���oM�����"A�Z�#$�J������e��j�0{ ��$i@��e�s����:�33���3C�y�L �Y�q�gVqi͊�֏,�
nCʙ2N���X���W�:Ȫ This double burner unit has been specifically designed to be inset into your countertop. /T1_0 27 0 R 10 0 obj /Bibliography /BibEntry �O�Od��l�cL3�1`� ��dzV&b���F�@�_C���%:6`bϼ��K�ZdN�ՙ@g�)$��g�J��a�t|��H��O;�^]z8hN�ۈ=���D�S��b;�wV@b?�DA��HUy^0!�� "\��'OJ�N���3��Eay�$���۠7�}�܇c��"h�*��W�1rR{Nj�s�$��2D:O��S )��������C���� /GS0 26 0 R >> 1 2 3 MINIMUM LINE HEIGHTS USING CONDUCTOR SAG TABLES Electric Cooktops This clearance varies by model. clearance height See label next to name plate for minimum clearance to rear wall. This clearance may be reduced to 600 mm (24 in.) A minimum clearance of 24 inches ⦠/Type /Page >> /S /Sect Hawkins, William GR 2" MIN. /Type /Outlines If you have an induction or an oven and are wondering if induction cooktops can be installed over an oven, the answer is yes. Freestanding or built-in ranges shall have a vertical clearance above the cooking top of not less than 30 inches (762 mm) to unprotected combustible material. /ExtGState << /InlineShape /Figure 3: Yes, about ½ of the second cupboard door overhangs the cooker. 19. 7 0 obj << For island installation, maintain 2-1/2 in. /Resources << Use this guide (and its reviews) to learn how to … M1901.1 Clearances. /T1_2 32 0 R (1) Except as provided in Sentence (2), framing, finishes and cabinetry installed directly above the location of the cooktop shall be not less than 750 mm above the level of cooktop burners or elements. endstream /StructTreeRoot 5 0 R Cooktops Cooktops Induction cooktops Gas cooktops Glass ceramic cooktop Did you know An induction cooktop is up to 50% more energy efficient compared to a ceramic or a radiant cooktop. /MarkInfo << /Nums [0 [42 0 R 45 0 R 46 0 R 47 0 R 48 0 R 51 0 R 52 0 R 53 0 R 54 0 R 55 0 R /T1_3 39 0 R Over The Range (OTR) Microwave hoods require a vertical clearance of 17" to 20" from cooking surface. endobj << /Annots [35 0 R 36 0 R] /Resources << /T1_5 27 0 R OUTDOOR Voltage in KV Phase⦠/Length 1232 /MediaBox [0.0 0.0 612.0 792.0] /Kids [9 0 R 10 0 R] /ColorSpace << /MediaBox [0.0 0.0 612.0 792.0] The minimum clearance required directly above the cooktop is 750 mm (30") to combustibles. /Producer (Adobe PDF Library 15.0) /P 5 0 R /Pages 4 0 R for a minimum of 18" above the cooking surface. 1 1/2â min. Kitchen Cabinet Clearance Above Stove Top Installers discuss the rules for installing cabinets or a microwave and vent hood above a kitchen range. /Metadata 2 0 R B Minimum vertical distance between countertop and cabinet extending above counter 18” (457) 18” (457) 18” (457) C Minimum clearance from left and right edge of cooktop to nearest vertical combustible surface 12” (305) 12 D TILLREDA Portable induction $ 49. >> endobj /Tabs /S Climbing Space is an unobstructed, vertical space along the side or corner of the pole. Cooktops have knobs on the counter's surface, beside the burners, whereas rangetops have knobs that sit below the surface of the counter at a vertical orientation. H��Vێ�6}�W�Q".o�t�M�I7]}���*��]��%��}g��,�Ҿ�Ų(��̙3�V+����B /StructParents 1 83 0 R 84 0 R 85 0 R 86 0 R 88 0 R 89 0 R 90 0 R 91 0 R 92 0 R 93 0 R Is it possible to recirculate my ventilation hood? Watch out to be sure you have adequate clearance space under the countertop too - you need at least 3 9/16" total clearance under the counter or put another way, you need at least 7/16" clearance to … cbї�+1�X�U�m�Ʊ�B�y =he�F9 v� .�Ғ�8g��c]G���`"$��R��\Png�b�4)ԣ�UC�Y�s� 2�+�^_AS��-�!�p�ز�� �g?����l����~��Ld>� �|JѡE�h�*�K����1�J�*k^jzT˗I_1�Yx�T���*ou�`����^g�Xs������Z~ys�u1�����[�;)�3zWE�����^�n"i�W�shsp��D���|.h5Yu 2019-09-24T15:30:42-06:00 >> have a vertical clearance above the cooking top of not less than 30 inches to combustible material or metal cabinets. Adobe PDF Library 15.0 stream
/Parent 3 0 R 1. minimum clearance distance. NOXTON Ceramic Cooktop Built-in 2 Burners Electric Cooktops Stove Electric Hob Cooker With Touch Control Child Lock Timer Easy To Clean 3000W with Hard Wire for 220V~240V 4.3 out of 5 stars 43 Tools & Home Improvement /Contents 37 0 R 3 0 obj 2: There is no extraction fan above the cooker, just the cupboard as described above. 09.00-00A DWG. stream
/A 14 0 R >> n��
8 0 obj /ParentTree 12 0 R above the 36” (91.4 cm) counter height. Remember, ‘drying heights’ are measured from Chart Datum (CD) and give an indication of how much of the seabed / intertidal zone will be above sea level around Lowest Astronomical … 1 [75 0 R 76 0 R 77 0 R 78 0 R 79 0 R 80 0 R 81 0 R 82 0 R 109 0 R null << /Font << Electrical supply location only applies to installations wi th built-in oven. /ParentTreeNextKey 2 ?FI�R2�"�v����`�3l=�/�>���5�0���|FT��P����E���aE8��%ISQC9�~C�� h��4!Y�
�p�L� �q�N/�jy�1Ģ�-i�>1�E@�����
�RE�qXR�ϊ����a����!��Аӯ#Tu0��hhJ #�/)�47���>�(�Ƨ�2��>��S����L�*f�uʅ�Z�=F�$�1��Xz�&��`��g�#�W���{7)�f�5�I��g!�-� u���
Freestanding or built-in ranges shall have a vertical clearance above the cooking top of not less than 30 inches (762 mm) to unprotected combustible material.Reduced clearances are permitted in accordance with the listing and labeling of the range hoods or appliances.. These models are supplied with 10Amp plug and lead * Minimum height of non-combustible surface is 150mm NOTE: All appliances must be installed to Australian Standard AS5601 minimum distance to combustible vertical surface minimum distance to non-combustible vertical surface* A 135mm 50mm B 120mm 50mm gas cooktop MODEL: GHL46 Remember, âdrying heightsâ are measured from Chart Datum (CD) and give an indication of how much of the seabed / intertidal zone will be above sea level around Lowest Astronomical Tide (LAT) when the tide goes fully out. /CS0 [/ICCBased 25 0 R] << Mj�`a�f�]N���_mxي�;^�� �um~�ؚ�x��}#@�u:��
p Oǜ&���Z����U���w�e�h�s�#��"�nY��H ��2w
�YCJ;P��κ��nr�T�����GEU�����=�0����2�(��ZE��4�P�y�忐�����Ԍ_�\�- endobj A question was whether the new countertop would be deeper and whether it might or might not have adequate vertical clearance space above a built-in oven installed below this countertop. << Where the manufacturers of the gas cooking appliance and the rangehood / exhaust fan do not specify a minimum clearance rate, then the practitioner must provide a clearance rate of no less than 600mm for a rangehood and no less than 750mm for an exhaust fan, in accordance with ⦠and you need at least 30" above the cooktop to any overhead cabinet over the cooktop and 18" vertical clearance from those left and right 12" free clearance side areas too.